What are you looking for?
Please choose region, country and your language

Air cleaners

Air cleaner systems from MANN+HUMMEL convince with excellent filtration performance. Harmful dirt particles and water droplets are separated from the intake air, thus reducing wear on the engine and extending its service life. Depending on the area of application, various functions such as acoustic measures or pre dust- and water separators can be integrated. In addition to customer-specific air cleaner systems that make the best possible use of even complex installation spaces, our portfolio also includes standard air cleaners that can be flexibly adapted to your application.

Luftfilter IQORON

IQORON

Volume flow range 4 m³/min to 12 m³/min
Operating temperature Continuous: -30 °C to +100 °C; Short-term: +120 °C
Pre-separation Multi-cyclone block
Selection criteria High power density, compact design and long service life, scavenging required
Learn more
IQORON-V

IQORON-V

Volume flow range 3 m³/min to 14 m³/min
Operating temperature Continuous: -40 °C to +100 °C; Short-term: +120 °C
Pre-separation Multi-cyclone block
Selection criteria High power density, compact design, flexibility and long service life, dust discharge via valve does not require scavenging, scavenging as option
Learn more
IQORON-S

IQORON-S

Volume flow range 4 m³/min to 10 m³/min
Operating temperature Continuous: -30 °C to +90 °C; Short-term: +110 °C
Pre-separation -
Selection criteria High power density, compact design, flexibility, low pressure drop
Learn more
IQORON VP

IQORON VP

Volume flow range 14 m³/min to 33 m³/min
Operating temperature Continuous: -40 °C to +80 °C
Pre-separation Multi-cyclone block
Selection criteria High power density, compact design flexibility and long service life, dust discharge via valve
Learn more
ENTARON XD

ENTARON XD

Volume flow range 7 m³/min to 40 m³/min
Operating temperature Continuous: -30 °C to +90 °C; Short-term: +110 °C
Pre-separation Tangential inlet
Selection criteria High power density for conditions with very high mechanical stress, excellent flexibility through variable modular system, long service life, scavenging as option
Learn more
ENTARON MD

ENTARON MD

Volume flow range 20 m³/min to 40 m³/min
Operating temperature Continuous: -30 °C to +80 °C; Short-term: +110 °C
Pre-separation Single-stage air cleaner - optionally extendable to combination air cleaner with separate DualSpin
Selection criteria Low flow resistance (single-stage air cleaner) or maximization of service life (combination air cleaner)
Learn more

ENTARON XR

Volume flow range 17 m³/min to 28 m³/min
Operating temperature Continuous: -30 °C to +80 °C; Short-term: +110 °C
Pre-separation Tangential inlet
Selection criteria Flexibility and economy with a long service life, self-cleaning
Learn more
ENTARON HD

ENTARON HD

Volume flow range 2 m³/min to 13 m³/min
Operating temperature Continuous: -30 °C to +80 °C; Short-term: +110 °C
Pre-separation Tangential inlet
Selection criteria Compact dimensions, flexibility and economy with a long service life
Learn more
ENTARON CD

ENTARON CD

Volume flow range 2 m³/min to 13 m³/min
Operating temperature Continuous: -30 °C to +80 °C; Short-term: +110 °C
Pre-separation -
Selection criteria Low pressure drop and excellent economy with low dust loads (single-stage air cleaner), compact dimensions
Learn more
NLG Pico

NLG Pico

Volume flow range 10 m³/min to 45 m³/min
Operating temperature Continuous: -40 °C to +80 °C; Short-term: +100 °C
Pre-separation -
Selection criteria Low pressure drop and excellent economy with low dust loads
Learn more
NLG Piclon

NLG Piclon

Volume flow range 10 m³/min to 40 m³/min
Operating temperature Continuous: -40 °C to +80 °C; Short-term: +100 °C
Pre-separation Guiding vanes to generate air spin
Selection criteria Excellent economy with medium dust loads, scavenging as option
Learn more
NLG DualSpin Kombinationsfilter

NLG DualSpin Kombinationsfilter

Volume flow range 18 m³/min to 50 m³/min
Operating temperature Continuous: -40 °C to +80 °C; Short-term: +100 °C
Pre-separation External mono-cyclone with integrated pressure recovery (DualSpin)
Selection criteria long service life with high dust loads
Learn more

Air cleaner

for passenger cars

  • Tailor-made solutions for individual customer needs
  • Various element geometries for optimum use of the available installation space
  • Diverse functional integration possible, for example acoustic components or water separators

Air cleaner

for heavy duty applications

  • Tailor-made solutions for individual customer needs
  • Various element geometries for optimum use of the available installation space
  • Pre-Separation optionally as integrated multi-cyclone or via tangential air inlet

Heavy-Duty and Industry Online Shop

In our Heavy-Duty and Industry Online Shop you will find our standard components for Heavy-Duty and Industry applications which can be ordered quickly and easily.

 

Visit our Online Shop

Downloads

Find out more about technical details, characteristics and order numbers in our catalogs, installation and maintenance instructions.